IFX-F100 ISOFLUX Ultrasonic Flowmeter Clamp - On for Fixed Installation

Measuring principle | : | Transit time |
Velocity range | : | 0.01 - 25m/s |
Resolution | : | 0.25 mm/s |
Repeatability | : | 0.15% of measured value |
Accuracy (Flow/Volume) | : | ±1.3% of measured value depending on application ±0.5% of measured value with process calibration against master meter |
Accuracy (Velocity) | : | ±0.5% of measured value |
Measurement rate | : | 1 Hz as standard |
Response time | : | 1 second |
Damping of reading | : | 0 ... 99 seconds (selectable) |
Solids and gas content in media | : | < 10% in volume |
Enclosure | : | Robust ABS housing with rubber shock protector |
Protection rate | : | IP65 (EN60529) |
Ambient temperature | : | -10 + 60°C (for electronics) |
Supply | : | internal rechargeable batteries |
Operation time | : | up to 24 hours with fully charged batteries |
Display | : | LCD graphic with back light |
Weight (approx.) | : | 0.65kg (instrument only); 7kg (transport case with instrument and sensors) |
Operating languages | : | English, Spanish, Italian (other on request) |